LG-104
Seal-It |
Seal-It! Deep Penetrating Sealer
(TS-104)
permanently seals and densifies concrete, plaster and Gunnite.
Moreover, it increases the bonding power of paint by up to 300%
making it a compelling choice. Withstands hydrostatic pressure
up to an amazing 60 PSI! Not a coating; it
does not leave a finish behind because 100% is absorbed by
porous surfaces. Creates a permanent water barrier increasing
compressive and flexural strength in the process. It contains a
catalyst that seeks out and reacts with moisture, free alkali
(lime), calcium hydroxides and other particles present within
the matrix fusing them together creating an impenetrable silica.
The entire surface penetrated is impregnated and converted
turning the entire structure into a solid mass preventing the
movement of moisture permanently. It is important to use
the TS-695 Etching Cleaner after applying Seat-It.
Seal-It! is a chemically reactive deep penetrating sealant that
works internally within the concrete matrix; not as a surface
sealant. It does not alter or affect the color or texture of the
surface treated. It retards penetration of grease, oils, wax and
acids. Cures new concrete uniformly, resists hair checking, retards
pitting, dusting, rutting and displaces grease and oil. Densifies
and hardens surfaces extending the life of treated surfaces by
reducing or eliminating wear due to abrasion, freeze-thaw and salt
attack.
Not intended for use on non-porous surfaces. Acceptable for use on
Portland cement, concrete, gunnite, stucco, plaster, porous tile,
shotcrete and mortar. Point of refusal is typically reached at three
applications. Treats 150—200 square feet per gallon, per
application. Apply by Sure-Flow or pump-jug sprayer. It is zero VOC,
nontoxic and not HAZMAT. Available in one gallon and five gallon
containers.
MSDS
Performance Data Sheet
Application Instructions
This information has been prepared
for use with Seal-It! Deep Penetrating Sealer on properly
prepared surfaces. Seal-it! is zero VOC, nontoxic and it is not
HAZMAT. It not a coating, it is a deep penetrating sealant, 100%
of which is intended to penetrate the surface leaving no residue
behind. It works by acting as a catalyst to combine components
within the concrete matrix to create an impenetrable barrier to
moisture and vapor transmission. It is acceptable for use on
Portland cement, concrete, stucco, porous tile, Gunnite,
Shotcrete and mortar. It does not alter or affect the color or
texture of the surface treated. It retards the penetration of
grease, oils, wax and acids, cures new concrete uniformly,
resists hair checking, retards pitting, dusting, rutting and
displaces grease and oil. New concrete must be allowed to cure
28 days or more before application. To avoid penetration and
curing issues we recommend establishing the accurate amount of
vapor transmission and pH level prior to application. Prior to
the application of paint or coating products porous substrates
must test at no more than 4LBS hydrostatic pressure with pH
under 9. We recommend utilizing the VaporGuage calcium chloride
moisture test, or the equivalent. Never apply in hot direct
sunlight or when rain is forecast within 48 hours. Under most
circumstances allow 24-48 hours between coats.
Surfaces
testing above 4 lbs hydrostatic pressure should be retested
after the application of Seal-It! using the VaporGuage Test Kit
to ensure hydrostatic pressure has been reduced to acceptable
levels. Additional applications of Seal-it! may be required to
achieve desired results.
1. PREP-WORK:
Best results will be
achieved by sanding, grinding, blasting or similarly abrading
the surface, which opens the pores supporting penetration. All
repairs should be completed and allowed to cure prior to
sanding, blasting, grinding or the application of Seal-it! Use
the VaporGuage calcium chloride moisture test kit, or similar
method, to establish the level of vapor transmission and pH
before application.
2. CLEAN:
All applications will
require the complete removal of all sealants, paint or coatings,
grease, oil, glue, contaminates and similar substances that may
prevent proper penetration or proper curing. Triple Strength
Paint Stripper (TS-646) may be used to remove paint and
coatings. Mastic remover will remove glue and industrial
degreaser, TSP and similar products will remove grease and oil.
Seriously contaminated areas may require resurfacing. Power-wash
as needed to remove dirt and grime. Recommend using TS-695
Etching Cleaner or muriatic acid to open the pores. Muriatic
acid should be properly neutralized. TS-695 Etching Cleaner or
muriatic acid should be used after the Seal-It and before
applying paint.
3. APPLY SEAL-IT!:
Lightly pre-wet
surfaces which promote penetration. Most applications are by
hand pump sprayer, however brush and roller coat applications
are acceptable. Apply evenly avoiding puddling. Under ideal
circumstances allow 24-48 hours between coats and 72 hours to
cure.
4. REPEAT APPLICATIONS:
Best results
will be achieved by three applications of Seal-It!. Let stand
24-48 hours between applications. Apply evenly avoiding puddling.
Never apply paint or coating products before Seal-It! has been
allowed to cure fully.
NOTE: Under
ideal circumstances best results will be achieved by allowing
5-7 days for Seal-It to cure before applying coating products.
In situations where there is an unusually high level of
hydrostatic pressure allow as many as 30 days for Seal-it! to
cure before applying coating products. Where extremely high
levels of hydrostatic pressure exist we recommend doing
additional VaproGuage calcium chloride tests to confirm the
post-treatment hydrostatic pressure level. Where hydrostatic
pressure exceeds 4 LBS apply additional coats of Seal-it! until
calcium chloride tests are below 4LBS. We hope this information
helps you achieve the results you expect and years of problem
free service. We are available to answer questions at
360-651-9050 M-F 9 AM to 5 PM PST.
|